Hard Water Quotes

DIY Fleck 5600SXT Install: What You Need Before You Start

A Fleck 5600SXT is the valve on most "DIY water softener" systems sold online. Installing one is ordinary plumbing: cut into the main line, add a bypass, run a drain line and a brine line, then program the valve. This page lists what Pentair's own manuals require so you can decide if it's a weekend job or a call to a plumber, and so you can check a pro's work. Everything here comes from Pentair's 5600SXT manuals and Hillsborough County's permit pages; your system's manual is the final word.

Check your site first

RequirementWhat Pentair's manuals say
Water pressure20 to 125 psi. Below 20 psi the regeneration valve won't work well; above 125 psi you need a pressure regulator.
TemperatureRoom between 34°F and 120°F. Water temperature limit is 100°F in the Pentair system manual and 110°F in the Fleck valve service manual. Never let it freeze.
Distance to water heaterAt least 10 feet of pipe between the softener and the water heater, so hot water can't back up into the system.
DrainA floor drain, standpipe, or tub as close as possible; ideally within 20 feet.
PowerA grounded outlet that is always on, not on a switch. The SXT keeps time for at least 8 hours in an outage.
Floor and accessLevel, firm floor with room to service the valve and add salt.
Outdoors (common in Florida garages and side yards)Pentair recommends indoors. The valve is rated NEMA 3, so falling rain is OK, but not constant mist, corrosive air, or sprinkler spray from below. Sun fades the plastic but Pentair says it won't cause failure.
Existing pipesReplace piping heavily built up with lime or iron. If it's clogged with iron, put an iron filter ahead of the softener (see iron filter vs softener).

Parts and supplies checklist

The rules people get wrong

Start-up, step by step

  1. Put about 1" of water in the brine tank above the grid plate (or to the top of the air check if there's no grid). No salt yet.
  2. With the bypass in "bypass," turn the water on and run a nearby cold tap to flush out solder bits.
  3. Rotate the bypass handles 2 to 3 times to seat the O-rings, then slowly move to "service" and let the tank fill. Run a cold tap to purge air.
  4. Plug in the transformer and program the valve (below).
  5. Hold Extra Cycle for 5 seconds to start a regeneration. In backwash, run until the drain water is clear (about 10 minutes).
  6. Advance with Extra Cycle to brine draw and confirm it pulls water from the brine tank, then rapid rinse until clear (about 5 minutes), then brine refill.
  7. Add salt.

Programming basics

Permits in Hillsborough County

DIY or hire it out?

Coming soon: links to DIY Fleck 5600SXT systems, bypass kits and install parts.